Infl uence exerted by thermal changes in the transverse defl ection of acrylic materials used for denture bases, with and without metallic inserts

Alejandro Osorio Naranjo, Jorge Guerrero Ibarra, Alejandro Santos Espinoza

Resumen


The aim of the present in vitro study was to determine whether thermal changes infl uence the transverse defl ection of two different brands of acrylic used for denture bases, with and without metallic inserts, after having been subjected to a thermo-cycling period with temperature changes. 40 acrylic samples were processed according to ADA’s specification number 12. Four groups were made up, two with Lucitone 199 and two with ProBase Hot. Results were subjected to one-way ANOVA statistical analysis and comparison of Turkey groups with a value of (p > .001). Conclusion: Both acrylic materials used for denture bases fulfi ll specifi cations of ADA’s norm number 12. Metallic inserts allowed the decrease of the acrylic deflection and thermal changes considerably affected physical characteristics

Palabras clave


Deflection, acrylic, thermal, denture

Texto completo:

PDF


DOI: http://dx.doi.org/10.22201/fo.1870199xp.2014.18.3%20Ing.69661


Contacto:

Esp. Daniela Carmona Ruiz

danyelacarmona@gmail.com

Tel. (55) 5623 22 07